Oil-free air compressors
Oil-free piston, scroll and dry screw compressors. The air still needs drying and filtration; hospital medical air is a dedicated medical-gas design.
Series
DENAIR DWW oil-free scroll compressor
Quiet scroll compressor with an oil-free compression chamber, 2.2-44 kW.
- Power: 2.2-44 kW
- Flow: 0.22-4.79 m³/min
- Pressure: 7 / 8 / 10 bar
- Noise: 65-86 dB(A)
DENAIR dry oil-free screw compressor
Dry oil-free screw compressor (two-stage on the 7-10 bar models), 45-500 kW.
- Power: 45-500 kW
- Flow: 5.1-86.01 m³/min
- Pressure: 7-10 bar (low-pressure version 2.5-3 bar)
- Cooling: air or water (W)
SAYI SY-SF oil-free scroll compressor
Quiet oil-free scroll compressor with digital controller.
- Power: 2.2-7.4 kW (3-10 HP)
- Flow: 0.24-0.8 m³/min
- Pressure: 8 bar (SY-SF5: 7-10 bar)
Models
| Model | Flow (l/min) | Flow basis | Pressure (bar) | Power | Tank (L) |
|---|---|---|---|---|---|
| AC-F2-24 | 135 | Displacement (intake) · ≈ 88 FAD, est. | 8 | 1.1 HP | 24 |
| W-AC-F2 Whisper | 135 | Displacement (intake) · ≈ 88 FAD, est. | 8 | 1.1 HP | 6 |
| W-AC-F2 (horseshoe receiver) | 135 | Displacement (intake) · ≈ 88 FAD, est. | 8 | 1.1 HP | |
| W-AC-F2-6 | 135 | Displacement (intake) · ≈ 88 FAD, est. | 8 | 1.1 HP | 6 |
| AC-F2X2-50 | 270 | Displacement (intake) · ≈ 176 FAD, est. | 8 | 2.1 HP | 50 |
| AC-F2X2-68 | 270 | Displacement (intake) · ≈ 176 FAD, est. | 8 | 2.1 HP | 68 |
| AC-F2X3-120 | 405 | Displacement (intake) · ≈ 263 FAD, est. | 8 | 3.2 HP | 120 |
| AC-F2X4-250 | 540 | Displacement (intake) · ≈ 351 FAD, est. | 8 | 4.3 HP | 250 |
| AC-F3-50 | 200 | Displacement (intake) · ≈ 130 FAD, est. | 8 | 1.5 HP | 48 |
| AC-F3-68 | 200 | Displacement (intake) · ≈ 130 FAD, est. | 8 | 1.5 HP | 68 |
| HC50 2V-50 | 200 | Displacement (intake) · ≈ 130 FAD, est. | 8-10 | 2 HP | 50 |
| HC50 2V (horseshoe receiver) | 200 | Displacement (intake) · ≈ 130 FAD, est. | 10 | 2 HP | |
| W-AC-F4-50 | 260 | Displacement (intake) · ≈ 169 FAD, est. | 8 | 2 HP | 50 |
| W-AC-F4 (horseshoe receiver) | 260 | Displacement (intake) · ≈ 169 FAD, est. | 8 | 2 HP | |
| AC-F3X2-120 | 400 | Displacement (intake) · ≈ 260 FAD, est. | 8 | 3 HP | 120 |
| AC-F3X2-50 | 400 | Displacement (intake) · ≈ 260 FAD, est. | 8 | 3 HP | 50 |
| HC50 4V-250 | 400 | Displacement (intake) · ≈ 260 FAD, est. | 10 | 4 HP | 250 |
| HC50 2VX2-250 | 400 | Displacement (intake) · ≈ 260 FAD, est. | 10 | 4 HP | 250 |
| HC50 2VX2-120 | 400 | Displacement (intake) · ≈ 260 FAD, est. | 8-10 | 4 HP | 120 |
| HC50 2VX2 (base plate) | 400 | Displacement (intake) · ≈ 260 FAD, est. | 10 | 4 HP | |
| HC50 4V-120 | 400 | Displacement (intake) · ≈ 260 FAD, est. | 8-10 | 4 HP | 120 |
| HC50 4V (base plate) | 400 | Displacement (intake) · ≈ 260 FAD, est. | 10 | 4 HP | |
| W-AC-F4X2-120 | 520 | Displacement (intake) · ≈ 338 FAD, est. | 8 | 4 HP | 120 |
| W-AC-F4X2 (horseshoe receiver) | 520 | Displacement (intake) · ≈ 338 FAD, est. | 8 | 4 HP | |
| AC-F3X3-120 | 600 | Displacement (intake) · ≈ 390 FAD, est. | 8 | 4.5 HP | 120 |
| HC50 4V+HC50 2V (base plate) | 600 | Displacement (intake) · ≈ 390 FAD, est. | 10 | 6 HP | |
| HC502VX3-250 | 600 | Displacement (intake) · ≈ 390 FAD, est. | 8-10 | 6 HP | 250 |
| HC502VX3-400 | 600 | Displacement (intake) · ≈ 390 FAD, est. | 10 | 6 HP | 400 |
| HC502VX3 (horseshoe receiver) | 600 | Displacement (intake) · ≈ 390 FAD, est. | 10 | 6 HP | |
| W-AC-F4X3-120 | 780 | Displacement (intake) · ≈ 507 FAD, est. | 8 | 6 HP | 120 |
| W-AC-F4X3-250 | 780 | Displacement (intake) · ≈ 507 FAD, est. | 8 | 6 HP | 250 |
| AC-F3X4-250 | 800 | Displacement (intake) · ≈ 520 FAD, est. | 8 | 6 HP | 250 |
| AC-F3X4 (horseshoe receiver) | 800 | Displacement (intake) · ≈ 520 FAD, est. | 8 | 6 HP | |
| HC50 4VX2-400 | 800 | Displacement (intake) · ≈ 520 FAD, est. | 8-10 | 8 HP | 400 |
| HC50 4VX2 (base plate) | 800 | Displacement (intake) · ≈ 520 FAD, est. | 10 | 8 HP | |
| AC-F3X5-400 | 1,000 | Displacement (intake) · ≈ 650 FAD, est. | 8 | 7.5 HP | 400 |
| HC50 4VX2-250 | 800 | Displacement (intake) · ≈ 520 FAD, est. | 8-10 | 8 HP | 250 |
| W-AC-F4X4-400 | 1,040 | Displacement (intake) · ≈ 676 FAD, est. | 8 | 8 HP | 400 |
| W-AC-F4X4 (horseshoe receiver) | 1,040 | Displacement (intake) · ≈ 676 FAD, est. | 8 | 8 HP | |
| HC50 4VX3-400 | 1,200 | Displacement (intake) · ≈ 780 FAD, est. | 10 | 12 HP | 400 |
| HC50 4VX3 (acoustic enclosure) | 1,200 | Displacement (intake) · ≈ 780 FAD, est. | 10 | 12 HP | 30 |
| HC50 2VX5-400 | 1,000 | Displacement (intake) · ≈ 650 FAD, est. | 10 | 10 HP | 400 |
| W-AC-F4X5-250 | 1,300 | Displacement (intake) · ≈ 845 FAD, est. | 8 | 10 HP | 250 |
| HC50 4VX3 (base plate) | 1,200 | Displacement (intake) · ≈ 780 FAD, est. | 10 | 12 HP | |
| HC50 4VX5 (base plate) | 2,000 | Displacement (intake) · ≈ 1,300 FAD, est. | 10 | 20 HP | |
| HC50 4VX4 (base plate) | 1,600 | Displacement (intake) · ≈ 1,040 FAD, est. | 10 | 16 HP | |
| VS204-50 | 200 | Displacement (intake) · ≈ 130 FAD, est. | 8 | 2 HP | 48 |
| VS204X2-120 | 400 | Displacement (intake) · ≈ 260 FAD, est. | 8 | 4 HP | 120 |
| VS204X2-250 | 400 | Displacement (intake) · ≈ 260 FAD, est. | 8 | 4 HP | 250 |
| VS204X3-250 | 600 | Displacement (intake) · ≈ 390 FAD, est. | 8 | 6 HP | 250 |
| VS204X3-400 | 600 | Displacement (intake) · ≈ 390 FAD, est. | 8 | 6 HP | 400 |
| VS204X4-400 | 800 | Displacement (intake) · ≈ 520 FAD, est. | 8 | 8 HP | 400 |
| VS204X5-400 | 1,000 | Displacement (intake) · ≈ 650 FAD, est. | 8 | 10 HP | 400 |
| DWW-2 | 250 | FAD at 7 bar | 7-10 | 3 HP | |
| DWW-3 | 400 | FAD at 7 bar | 7-10 | 5 HP | |
| DWW-5 | 510 | FAD at 7 bar | 7-10 | 7 HP | |
| DWW-7 | 800 | FAD at 7 bar | 7-10 | 10 HP | |
| DWW-11 | 1,200 | FAD at 7 bar | 7-10 | 15 HP | |
| DWW-16 | 1,600 | FAD at 7 bar | 7-10 | 22 HP | |
| DWW-18 | 2,000 | FAD at 7 bar | 7-10 | 25 HP | |
| DWW-22 | 2,400 | FAD at 7 bar | 7-10 | 30 HP | |
| DWW-27 | 2,990 | FAD at 7 bar | 7-10 | 37 HP | |
| DWW-33 | 3,200 | FAD at 7 bar | 7-10 | 45 HP | |
| DWW-38 | 4,000 | FAD at 7 bar | 7-10 | 50 HP | |
| DWW-44 | 4,790 | FAD at 7 bar | 7-10 | 60 HP | |
| DWW-45 | 7,700 | FAD at 7 bar | 7-10 | 60 HP | |
| DWW-55 | 9,600 | FAD at 7 bar | 7-10 | 75 HP | |
| DWW-75 | 12,120 | FAD at 7 bar | 7-10 | 100 HP | |
| DWW-75W | 12,120 | FAD at 7 bar | 7-10 | 100 HP | |
| DWW-90 | 13,130 | FAD at 7 bar | 7-10 | 120 HP | |
| DWW-90W | 13,130 | FAD at 7 bar | 7-10 | 120 HP | |
| DWW-110 | 19,500 | FAD at 7 bar | 7-10 | 150 HP | |
| DWW-110W | 19,500 | FAD at 7 bar | 7-10 | 150 HP | |
| DWW-132 | 23,000 | FAD at 7 bar | 7-10 | 175 HP | |
| DWW-132W | 23,000 | FAD at 7 bar | 7-10 | 175 HP | |
| DWW-160 | 26,300 | FAD at 7 bar | 7-10 | 215 HP | |
| DWW-160W | 26,300 | FAD at 7 bar | 7-10 | 215 HP | |
| DWW-185 | 29,170 | FAD at 7 bar | 7-10 | 250 HP | |
| DWW-185W | 29,170 | FAD at 7 bar | 7-10 | 250 HP | |
| DWW-200W | 35,000 | FAD at 7 bar | 7-10 | 270 HP | |
| DWW-220W | 37,630 | FAD at 7 bar | 7-10 | 300 HP | |
| DWW-250W | 45,200 | FAD at 7 bar | 7-10 | 250 kW | |
| DWW-280W | 45,500 | FAD at 7 bar | 7-10 | 375 HP | |
| DWW-315W | 50,090 | FAD at 7 bar | 7-10 | 425 HP | |
| DWW-355W | 54,460 | FAD at 7 bar | 7-10 | 475 HP | |
| DWW-400W | 67,360 | FAD at 7 bar | 7-10 | 535 HP | |
| DWW-450W | 78,070 | FAD at 7 bar | 7-10 | 600 HP | |
| DWW-500W | 86,010 | FAD at 7 bar | 7-10 | 670 HP | |
| DWL-55-2 | 15,330 | FAD | 2.5 | 75 HP | |
| DWL-55-3 | 12,780 | FAD | 3 | 75 HP | |
| DWL-75-2 | 19,920 | FAD | 2.5 | 100 HP | |
| DWL-75-3 | 16,300 | FAD | 3 | 100 HP | |
| DWL-90-2 | 26,070 | FAD | 2.5 | 120 HP | |
| DWL-90-3 | 19,540 | FAD | 3 | 120 HP | |
| DWL-110(W)-2 | 33,160 | FAD | 2.5 | 150 HP | |
| DWL-110(W)-3 | 25,600 | FAD | 3 | 150 HP | |
| DWL-132(W)-2 | 40,240 | FAD | 2.5 | 175 HP | |
| DWL-132(W)-3 | 27,230 | FAD | 3 | 175 HP | |
| DWL-160(W)-2 | 49,420 | FAD | 2.5 | 215 HP | |
| DWL-160(W)-3 | 35,750 | FAD | 3 | 215 HP | |
| DWL-185(W)-2 | 55,180 | FAD | 2.5 | 250 HP | |
| DWL-185(W)-3 | 42,210 | FAD | 3 | 250 HP | |
| SY-SF3 | 240 | FAD | 8 | 3 HP | |
| SY-SF5 | 450 | FAD at 7 bar | 7-10 | 5 HP | |
| SY-SF7.5 | 600 | FAD | 8 | 7.5 HP | |
| SY-SF10-8 | 800 | FAD | 8 | 10 HP | |
| SY-SF5-250 | 450 | FAD at 7 bar | 7-10 | 5 HP | 250 |
| SY-SF7.5-250 | 600 | FAD | 8 | 7.5 HP | 250 |
Piston compressors: the catalogue figure is the intake displacement. The delivered air (FAD) is lower; the “est.” value is an estimate (65% of the displacement, 70% for a two-stage unit) for first sizing only, to be confirmed against the model's FAD data.
Models with several pressure versions: the flow shown is the lowest-pressure version; each product page lists the flow at every working pressure.